Phoenix Sensorless AC Vector Drive
US Drives, Inc.
Niagara Falls, NY

200 to 250VAC, 7.5 to 250HP

380 to 500VAC, 10 to 3000HP

500 to 600VAC, 10 to 3500HP

AC Drives

Download A Printable Word Version

Drive Order Form

Back to Drive Systems, Inc. Home

The Phoenix was designed with one goal in mind:
To create the most reliable and rugged AC Drive Control in the market today. Phoenix includes all the features required to operate in the most demanding industrial applications, yet it is simple to use.

Standard Features:
* TOLERATES HIGH INPUT AC LINE VOLTAGES
* SHORT CIRCUIT AND GROUND FAULT PROTECTION
* BUILT IN 3% DC BUS REACTOR
* BUILT IN RFI NOISE FILTER
* BUILT IN LINE VOLTAGE SURGE PROTECTION
* 50º C AMBIENT TEMPERATURE RATING
* ENGLISH LANGUAGE DISPLAY -2 LINE, 32 CHARACTER
* SPEED SENSITIVE OVERLOAD PROTECTION, MEETS NEC 430
* 2 SECOND POWER DIP RIDE THROUGH
* SETPOINT CONTROL WITH P. I. D.
* BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR)
* CUSTOM V/ HZ PATTERNS
* FIXED OR VARIABLE CARRIER FREQUENCY
* AUTOLOGGING FAULT HISTORY WITH TIME / DATE STAMP
* 8 CHANNEL DIGITAL CHART RECORDER WITH TIME / DATE STAMP
* MUCH, MUCH MORE...

Standard Options:
* AC LINE DISCONNECT SWITCH WITH FUSES
* MANUAL BYPASS / AUTOMATIC BYPASS
* NEMA 12 AND NEMA 4 ENCLOSURES
* PROCESS SIGNAL ISOLATION
* 115VAC OPERATOR INTERFACE KIT
* KW / KWH METERING
* HAND / OFF / AUTO OR LOCAL / REMOTE

Control:

Control Method: Sine coded PWM with programmable carrier. Space Vector control.
Output Voltage: 0 to rated voltage.
Output Frequency Range: 0 to 400 Hz.
Frequency Accuracy: Analog reference: 0.1% of max frequency.
Digital reference: 0.01% of max frequency.
Frequency Resolution: Analog reference: 0.06Hz at 60Hz.
Digital reference: 0.0005Hz at 60Hz.
Accel/Decel: Adjustable 0.1 to 3600 sec.
Drive Overload: High Overload Capacity Drives: 150% of drive rated output for two (2) minutes.
Normal Overload Capacity Drives: 120% of drive rated output for two (2) minutes.
Inverse Time Overload: Programmable for class 10, 20 and 30 protection with speed sensitive protection to comply with N.E.C. Article 430
Current Limit: Proactive current limit programmable in % of motor rated current.
Braking Torque: Approximately 20%.
V/HZ Curves: Custom curve programming plus nine (9) preprogrammed standard patterns.
Maximum Connected Motor: Two (2) times rated drive horsepower.
Control Power Ride-Thru: Two (2) seconds or greater, depending on load.
Ambient Temperature: 14 Deg F to 122 Deg F (-10 Deg C to 50 Deg C)
Input R.F.I. Filters: Standard
Construction: Steel Construction (Reduces E.M.I.)
Altitude: Sea Level to 3000 Feet
Surge Protection: Line transients to 6000V, IEEE C62-41-1991 Category B
Noise Immunity: Showering Arc 2000V Peak, EN50082-1,2

Electrical:

Rated Input Voltage: 200-250Vac, 380-500Vac, 500-600Vac -10% of minimum, +10% of maximum.
Rated Input Frequency: 48 to 63HZ.
Number of Phases: 3
Displacement Power Factor: .95 or greater
Efficiency: .97% or greater at rated current.

Phoenix AC Drive Dimensions*

Input Voltage

Motor HP

Drive Only

Drive With
Disconnect & Fuses

Drive With Bypass

High OL
Capacity**

Normal OL
Capacity***

NEMA 1

NEMA 12

NEMA 1

NEMA 12

NEMA 1

NEMA 12

200 - 250

7.5 - 30
30 - 60
75 - 100

10 - 30
40 - 75
100

27x13x12
33x21x14
33x21x14

30x20x14
48x24x18
48x24x18

42x13x12
65x21x14
65x21x14

30x20x14
48x24x18
48x24x18

42x13x12
65x21x14
72x30x21

42x36x18
72x30x23
72x30x23

380 - 500

10 - 60
75 - 150
150 - 200
250 - 400
450 - 600

15 - 60
75 - 150
200
250 - 400
450 - 600

27x13x12
33x21x14
33x21x14
90x36x25
90x48x25

30x20x14
48x24x18
48x24x18
90x36x25
90x48x25

42x13x12
65x21x14
65x21x14
90x36x25
90x36x25

30x24x14
48x24x18
60x24x18
90x36x25
90x48x25

42x13x12
65x21x14
72x30x21
90x48x25
90x72x25

42x36x18
72x30x23
72x30x23
90x48x25
90x72x25

500 - 600

10 - 60
75 - 100
125 - 200
250 - 400
450 - 600

15 - 60
75 - 125
125 - 200
250 - 400
450 - 600

27z13x12
33x21x14
33x21x14
90x36x25
90x48x25

30x20x14
48x24x18
48x24x18
90x36x25
90x48x25

42x13x12
65x21x14
65x21x14
90x36x25
90x36x25

30x24x14
48x24x18
60x24x18
90x36x25
90x48x25

42x13x12
65x21x14
72x30x21
90x48x25
90x72x25

42x36x18
72x30x23
72x30x23
90x48x25
90x72x25

*All dimensions are in inches
** High overload capacity drives produce 150% of rated drive output current for 2 minutes
*** Normal overload capacity drives produce 120% of rated drive output current for 2 minutes

Buy AC & DC Drives

Back to Drive Systems, Inc. Home
stripe.gif (1951 bytes)
Drive Systems, Inc. * 1606 Windswept Drive * Dickinson, Texas 77539 * Phone: 281-534-0255
(Houston lays in the shadow of Dickinson)